Citizen M7 IP Address Configuration

Citizen M7 IP Address Configuration

The IP address is set through parameters on the Citizen M7 control.  The first step is to set the password enabling write permissions for the settings.


     1.    Setting the Password

A.   Press the MAINT. button  on the operation panel.

B.   Press the I/F Diag  softkey.

C.   On the I/F Diagnosis page type “1001//M”.

D.   Press [Input]. 


    2.    Locating the Global IP Address

A.   Press the PRM. button on the operation panel.

B.   Press the Menu SEL  softkey until you see the BAS COM.  softkey.

C.   Press the BAS COM.  softkey and then press the operation panel’s page down  button until you see parameter #1925.

i.    The controller’s Global IP Address is parameter #1926.


  3.   Configuration Settings

A.   Use the cursor buttons to move to and highlight the associated parameter

            1925 (Ethernet) - Set to 1, this enabled the Ethernet port.
            1926 (Global IP Address*) - Set the IP
            1927 (Global Subnet Mask*) - Set the Subnet Mask
            1928 (Global Gateway*) - Set the Default Gateway, if the DX Service will be on a different subnet

B.   Press [Input].

Notes

Note: Value changes for all parameters with an asterisk (*) do not take effect until the control’s power is turned off then on. The asterisk will always appear even when the value does not have pending changes.

   

    • Related Articles

    • SRCE - Network Instructions

      Scytec SRCE IP Address Setup NOTE: PDF Download link at the bottom of the page Network Connectivity The Scytec Status Relay Controller Ethernet (SRCE) is Ethernet based and can be plugged into the network using a standard RJ-45 connection. It behaves ...
    • Configuring the Fanuc 31i Control

      The Fanuc control must be configured in order for the communication to take place. The configuration consists of setting standard TCP/IP network properties. The steps to configure the control may vary from model to model. The following steps are for ...
    • Siemens - OPCUA Activation

      OPC UA Activation on a Siemens 840D Solution Line or Simumerik ONE Check to see if you have the option "Access MyMachine /OPC UA 6FC5800-0AP67-0YB0" activated (Startup->Licenses). If the license is not enabled the license will need to be purchased ...
    • MTConnect - DMG Mori CELOS

      MTConnect is installed on new DMG Mori machines as standard. On a Celos control it must be enabled for use manually. To do so, navigate to the CELOS Connector Management application on the CELOS screen and click Machine Data on the left side. PDF ...
    • Configuring the Haas NGC

      Before DataXchange can communicate with this system, the IP address must be set on the control. Most HAAS NGC controls support a wired or a wireless Ethernet connection. For a wired connection Select the Wired Connection tab in the Network tabbed ...